Skip to main content

A service of Otto Zickwolff GmbH, Germany

Visit our shop →

Diese Seite auf Deutsch →

Dimension table · Gaskets

Flat gaskets to DIN 2690 (withdrawn): dimension table for existing plant

DIN 2690 set out the dimensions of flat gaskets for flanges with a flat sealing face. The inside diameter d1 follows the nominal size DN, and the outside diameter d2 additionally follows the pressure rating. The table covers DN 4 to DN 1400 and is fully verified in the DN 4–500 range against the manufacturer's dimension table KLINGER Information 70.1.1.

Standard
DIN 2690
Status
Withdrawn, replaced by DIN EN 1514-1
Type
Flat sealing face
Scope
PN 1 – PN 40
Nominal sizes
DN 4 – DN 1400

Note on standard status: DIN 2690 is withdrawn and has been replaced by DIN EN 1514-1. The dimensions below serve solely for identification and the maintenance of older plant and existing stock. For new designs, the contractually agreed, currently valid flange and gasket standards prevail – for flanges to DIN EN 1092-1 generally the relevant parts of the DIN EN 1514 series – along with the operating conditions and manufacturer specifications. In trade, orders to DIN 2690 are still placed in some cases – we supply the matching part.

Asbestos-free fibre-material flat gasket in ring form for the raised face
Flat gasket from the Zickwolff range: ring form for the raised face, inside Ø d1 by DN, outside Ø d2 by pressure rating. Image: Zickwolff shop

Good to know when cross-checking existing plant: the dimensions of DIN 2690 have largely been absorbed into the current DIN EN 1514-1 (form IBC – ring inside the bolt circle); for a few nominal sizes the EN values differ by a few millimetres. The current dimensions are set out on our page Flat gaskets to DIN EN 1514-1; for guidance on gasket forms and materials see the gaskets overview.

Tip: use Ctrl/Cmd + F to jump straight to the nominal size you need.

Inside Ø d1 and outside Ø d2 to DIN 2690, all dimensions in millimetres – availability: available (from stock or on order)
DN Inside Ø d1 PN 6 PN 10 PN 16 PN 25 PN 40 Availability
4630available
6102838383838available
8143343434343available
10183845454545available
15224350505050available
20285360606060available
25356370707070available
32437582828282available
40498592929292available
506195107107107107available
6577115127127127127available
8090132142142142142available
100115152162162168168available
125141182192192195195available
150169207218218225225available
(175)195237248248255267available
200220262273273285292available
250274318328330342353available
300325373378385402418available
350368423438445458475available
400420473490497515547available
(450)470528540557565572available
500520578595618625628available
600620680695735730745available
700720785810805830850available
800820890915910940970available
9009209901015101010401080available
1000102010901120112511501190available
1200122013051340134013601395available
1400142015201545154015751615available

"–" means: not documented in the source. Values in brackets (e.g. "(175)") mark less commonly used nominal sizes. For PN 1 and PN 2.5, use the PN 6 dimensions, except for DN 1200 (outside Ø 1290 mm) and DN 1400 (outside Ø 1490 mm). DN 60 is a special nominal size provided only for cast-iron flanges. Typical ordering information: "Gasket DIN 2690, DN 65, PN 40, material, s = 1.5 mm" – for new designs correspondingly "Gasket DIN EN 1514-1, form IBC, …".

Find the matching gasket directly

We carry flat gaskets matched to flanges and bolting from stock – cut-to-size and special materials on request. The overview shows which material suits which medium and temperature.

← Back to the gaskets overview

Technical basis: DIN 2690 (withdrawn; dimensions for identification and maintenance of existing plant). Dimension data DN 4–500 fully verified against the manufacturer's dimension table KLINGER Information 70.1.1 (flat gaskets to DIN EN 1514-1 and DIN 2690); DN 600–1400 from a distributor dimension table (BSA) with a documented QA correction for DN 800/PN 6. All information without guarantee – for new designs the current standard texts and the manufacturer's technical data sheets always prevail. Selection of values follows our delivery and stock programme; compiled from our own inventory management and long-standing trading practice, cross-checked against publicly available manufacturer data. This table does not replace the standard text – the currently valid standard always prevails. Editorially reviewed: July 2026. Standards and manufacturer status considered: July 2026.